{"id":1527,"date":"2026-03-18T02:49:39","date_gmt":"2026-03-18T02:49:39","guid":{"rendered":"https:\/\/en.esplaza.com.cn\/?p=1527"},"modified":"2026-03-18T02:49:39","modified_gmt":"2026-03-18T02:49:39","slug":"ul9540a-new-edition-of-key-bess-fire-safety-standard-establishes-new-precedent","status":"publish","type":"post","link":"https:\/\/en.esplaza.com.cn\/index.php\/2026\/03\/18\/ul9540a-new-edition-of-key-bess-fire-safety-standard-establishes-new-precedent\/","title":{"rendered":"UL9540A: New edition of key BESS fire safety standard \u2018establishes new precedent\u2019"},"content":{"rendered":"\n<p>The new edition of the UL9540A fire safety standard for battery energy storage systems (BESS) \u201cestablishes a new precedent in the testing and certification ecosystem.\u201d<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"450\" src=\"https:\/\/en.esplaza.com.cn\/wp-content\/uploads\/2026\/03\/image-9.png\" alt=\"\" class=\"wp-image-1528\" srcset=\"https:\/\/en.esplaza.com.cn\/wp-content\/uploads\/2026\/03\/image-9.png 800w, https:\/\/en.esplaza.com.cn\/wp-content\/uploads\/2026\/03\/image-9-300x169.png 300w, https:\/\/en.esplaza.com.cn\/wp-content\/uploads\/2026\/03\/image-9-768x432.png 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n<\/div>\n\n\n<p>UL Standards &amp; Solutions recently published (13 March) the 6<sup>th<\/sup>&nbsp;edition of the key standard, or the \u2018Test method for evaluating thermal runaway fire propagation in BESS,\u2019 to give its full title.<\/p>\n\n\n\n<p>UL9540A is widely recognised in the industry for assessing the safety of electrochemical energy storage systems (ESS), including, but not limited to, lithium-ion (Li-ion) BESS. It is considered the benchmark for evaluating safety, particularly in assessing thermal runaway and propagation risks and therefore critical to the bankability of energy storage technologies.<\/p>\n\n\n\n<p>The new edition adds requirements for&nbsp;<a href=\"https:\/\/www.energy-storage.news\/tag\/lsft\/\">large-scale fire testing (LSFT)<\/a>&nbsp;alongside cell and module level tests, perhaps aimed at overcoming a perceived limitation in previous versions by adding focus on system-level safety. In large-scale fire testing, a single BESS unit is set on fire with all its fire suppression and detection systems disengaged and the results observed, typically with other BESS units placed nearby to assess propagation risk.<\/p>\n\n\n\n<p>Commenting for&nbsp;<em>Energy-Storage.news<\/em>, Dana Parmenter, commercial VP of industrial at testing and certification provider CSA Group, said that the release of the 6<sup>th<\/sup>&nbsp;edition \u201cestablishes a new precedent in the energy storage system (ESS) testing and certification ecosystem.\u201d<\/p>\n\n\n\n<p>\u201cThis change will raise many questions for manufacturers around enforcement timelines, jurisdictional adoption, and how updated requirements may be interpreted by authorities having jurisdiction (AHJs),\u201d Parmenter said.<\/p>\n\n\n\n<p>\u201cThis edition expands testing expectations and introduces LSFT requirements within the certification process. Section 10 requires LSFT to demonstrate that fire will not propagate between ESS units. This change is part of a larger trend across ESS standards, placing greater emphasis on LSFT as it relates to system-level safety.\u201d<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-large-scale-fire-testing-mandatory-in-nfpa-855-2026\">Large-scale fire testing mandatory in NFPA 855 2026<\/h2>\n\n\n\n<p>Indeed, the growing emphasis on large-scale fire testing has been industry-wide. Many manufacturers and system integrators have been conducting LSFT on a voluntary basis as part of the adoption of best practices for the past year or so.<\/p>\n\n\n\n<p>Since then,&nbsp;<a href=\"https:\/\/www.energy-storage.news\/large-scale-fire-testing-lsft-from-best-practice-to-mandatory-requirement\/\">LSFT has become mandatory in the new 2026 edition<\/a>&nbsp;of the US National Fire Protection Association\u2019s BESS safety standard NFPA 855, as explained in a January 2026&nbsp;<em>Energy-Storage.news&nbsp;<\/em>article.<\/p>\n\n\n\n<p>Parmenter\u2019s company, CSA Group,&nbsp;<a href=\"https:\/\/www.energy-storage.news\/video-evolving-large-scale-fire-testing-requirements-for-battery-energy-storage-systems\/\">developed a technical specification protocol for LSFT<\/a>, as a companion to UL9540A.<\/p>\n\n\n\n<p>Parmenter said that while UL9540A now addresses NFPA 855\u2019s safety testing requirements, AHJs often request additional performance-based data to support site-specific evaluations of projects.<\/p>\n\n\n\n<p>\u201cNFPA 855 Section 9.2.1.2.1 requires large-scale fire testing to characterise gas composition and demonstrate non-propagation between ESS units, which inherently involves gas analysis and calorimetric data such as heat release rate (HRR). Previous editions of UL 9540A did not explicitly incorporate large-scale fire testing. The 6th Edition now addresses spacing and fire propagation as safety considerations within the certification framework,\u201d Parmenter said.<\/p>\n\n\n\n<p>CSA Group\u2019s&nbsp;<a href=\"https:\/\/www.energy-storage.news\/the-energy-storage-industrys-new-standard-for-safety-and-reliability-csa-c800-2025\/\">CSA\/ANSI C800:25 consensus-based standard to evaluate ESS reliability<\/a>&nbsp;includes many of the measurements of metrics required by NFPA 855, Parmenter said, including the interpretation of test results by a registered fire protection engineer.<\/p>\n\n\n\n<p>Many of those registered engineers \u201cstrongly recommend HRR and other measurements\u201d included in CSA\/ANSI C800:25 to support their analysis, Parmenter claimed, adding that the standard can be used alongside and as an extension of UL9540A because it provides additional performance and engineering-based data, such as HRR, gas composition, detection response, and BMS data to support site specific installation requirements, engineering approvals, and AHJ review.<\/p>\n\n\n\n<p>\u201cUL 9540A and CSA\/ANSI C800:25 now serve more distinct, yet complementary, roles within the ESS testing and approvals process. Looking ahead, both standards may be applied to support the demonstration of alignment with NFPA 855. UL\u2019s recent revisions to UL 9540A expand the scope of safety-focused requirements by incorporating certain performance-based considerations, such as those informing spacing and propagation mitigation, into the certification framework,\u201d Dana Parmenter said.<\/p>\n\n\n\n<p>\u201cWhile this approach reflects an increased emphasis on system-level safety, CSA\/ANSI C800:25 continues to provide additional performance and engineering-based characterisation, including data elements that remain optional or out of scope under UL 9540A.\u201d &nbsp;&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The new edition of the UL9540A fire safety standard for battery energy storage systems (BESS)&hellip;<\/p>\n","protected":false},"author":2,"featured_media":1528,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[],"class_list":["post-1527","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-policy"],"_links":{"self":[{"href":"https:\/\/en.esplaza.com.cn\/index.php\/wp-json\/wp\/v2\/posts\/1527","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/en.esplaza.com.cn\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/en.esplaza.com.cn\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/en.esplaza.com.cn\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/en.esplaza.com.cn\/index.php\/wp-json\/wp\/v2\/comments?post=1527"}],"version-history":[{"count":1,"href":"https:\/\/en.esplaza.com.cn\/index.php\/wp-json\/wp\/v2\/posts\/1527\/revisions"}],"predecessor-version":[{"id":1529,"href":"https:\/\/en.esplaza.com.cn\/index.php\/wp-json\/wp\/v2\/posts\/1527\/revisions\/1529"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/en.esplaza.com.cn\/index.php\/wp-json\/wp\/v2\/media\/1528"}],"wp:attachment":[{"href":"https:\/\/en.esplaza.com.cn\/index.php\/wp-json\/wp\/v2\/media?parent=1527"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/en.esplaza.com.cn\/index.php\/wp-json\/wp\/v2\/categories?post=1527"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/en.esplaza.com.cn\/index.php\/wp-json\/wp\/v2\/tags?post=1527"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}